DTMF Dialing

Use DTMF (dual-tone multi-frequency) to dial the
central station receiver phone number(s) for event
reports, and/or the D5300 Remote Account
Manager.
Default:
Yes
Selection:
Yes or No
Yes
Dials the programmed phone
number(s) using DTMF.
Pulse dialing only
No

Phone Supv Time

Sets the amount of time the panel continues to
monitor a faulted phone line before initiating phone
line trouble responses.
Default:
Blank
Selection:
Blank or 10 to 240
Blank
No phone line supervision.
Initiate phone line trouble response if
10 to 240
the phone line continues to be faulted
after the programmed amount of
seconds expire. After a faulted phone
line restores, it takes the same amount
of time to initiate restoral responses.
Make settings in ten sec. increments.
Bosch Security Systems | 2/04 | 74-06145-000-D
Panel Wide Parameter
Phone line trouble responses:
Command centers display SERVC PH LINE # and
sound the trouble tone.
Restoral
after it restores when a single phone line is used, if
Power/Phone
Trouble and restoral events are reported if
Power/Phone
Phone Line Module is installed, and one of the
phone lines is operational.

Alarm On Fail

Default:
Selection:
Yes
No

Two Phone Lines

Use when a Dual Phone Line Module is connected
to the D9112. Both lines must operate the same,
either ground start or loop start. NFPA standards
prohibit the use of ground start phone lines in
systems monitoring fire points.
Default:
Selection:
Yes
No
0101
0101
0101
reports identify the previously failed line
is enabled in Phone Routing.
is enabled in Phone Routing, a Dual
Yes
Yes or No
Generate alarm responses in Area 1
and trouble responses in all other areas
when a phone line fails.
Time
must be programmed to use this
feature.
Phone Failure Alarm Responses: An
alarm tone sounds at command centers
assigned to Area 1. The alarm bell
relay for Area 1 activates. The
Fail
relay activates if programmed in
Relay Parameters.
Trouble responses when a phone line
fails.
Phone Supv Time
programmed to use this feature.
No
Yes or No
Dual Phone Line Module installed.
The LEDs on the module light to
indicate primary or secondary line
trouble and Comm Fail.
No Dual Phone Line Module.
IMPORTANT! Program Phone Supv Time
when using two phone lines.