Point Text; Command 7; Point Index; Bfsk Code - Bosch D9112B Program Entry Manual

Control panel
Table of Contents

Advertisement

D9112B | Program Entry Guide | 8.0

Point Text

Default:
Command 9
Selection:
Up to 16 characters alphanumeric
Enter alphabetic characters A to Z
in capital letters
Note:
Period (.), comma (,), percent (%), parenthesis [()],
equal (=), greater/less than (< >), exclamation (!),
and colon (:) are not allowed.
Enter up to 16 characters of text to describe the
Command 9 function. This point text is displayed at
command centers (if the point is programmed as
"visible") and reported to the D6500 when
transmitting in Modem II ( if it is a reporting point).
8.3

Command 7

The Command 7 section defines how the Command 7
function operates. Program this section if
7
is enabled in the User Interface module.
This function generates an
area where the command center is assigned. A new
report is generated each time it is activated, but only
one alarm appears in the alarm memory count at the
local area command centers. If this function is
activated in more than one area within the scope of
the command center, the alarm memory count is
increased.

Point Index

Default:
4
Selection:
Blank or 00 to 31
Point Index
Enter the
0101
Point Index 00 (or blank) only works with
0101
Command 7 and Command 9. It is a silent,
0101
invisible, reporting point. Point Index 00
disables a normal point.
0101
Do NOT use a point index with Resettable
0101
programmed YES.
0101
Do NOT use a point index with Swinger
Bypass programmed YES.

BFSK Code

Default:
7
Selection:
Blank or 0 to 9
Bosch Security Systems | 2/04 | 74-06145-000-D
Point Assignments
User Cmd
Alarm
report from the
code used with Command 7.
Use this entry to determine the point number
reported in BFSK when this point is tripped.
Normally, you only use this item when transmitting
reports to the central station in BFSK format.
Command centers and local printers display the
actual point number (1 to 135) not the BFSK report
code.
Activating Relays: To activate a relay on the
D8129 OctoRelay or C8137 Transmitter Interface,
A# Command 7
see Relays
Point Text
Default:
Command 7
Selection:
Enter alphabetic characters A to Z
in capital letters
Note:
Period (.), comma (,), percent (%), parenthesis [()],
equal (=), greater/less than (< >), exclamation (!),
and colon (:) are not allowed.
Enter up to sixteen characters of text to describe the
Command 7 function. This point text is displayed at
command centers (if the point is programmed as
"visible") and reported to the D6500 when
transmitting in Modem II ( if it is a reporting point).
EN | 81
.