Initiating a Panic Alarm

You can generate a panic alarm manually in the
disarmed and armed states alike. The sequence will
be as shown:
PRESS
Note: If you are using a key-ring transmitter, press
both AWAY and HOME buttons (KF-234) or AUX1
and AUX2 (KF-237) simultaneously for 2 seconds.
To stop the alarm, press
your valid user code.

Initiating Fire Alarm

(This function is disabled in ACPO compliant version).
You can generate a fire alarm in disarmed & armed
states, as follows:
PRESS
To stop the alarm, press
your valid user code.

Initiating Emergency Alarm

You can generate an emergency alarm manually in
the disarmed and armed states, as follows:
PRESS

Disarming and Stopping Alarms

(This function is disabled in ACPO compliant version).
Disarming the system stops the siren before it stops
automatically, irrespective of whether the alarm was
initiated in the armed or the disarmed state.
After disarming, different displays may appear,
depending on the current status of the system:
A. Disarming - no events: After an uneventful
armed term the disarming operation will progress
as shown:
D-302757
OPERATING THE POWERMAX10-G2 SYSTEM
RESULTANT DISPLAY
PANIC ALARM
READY HH:MM
and then key in
RESULTANT DISPLAY
FIRE
Then, if or when the system
is in the disarmed state:
READY
HH:MM
(alternating)
READY MEMORY
and then key in
RESULTANT DISPLAY
EMERGENCY
Then, if or when the system
is in the disarmed state:
READY
HH:MM
(alternating)
READY MEMORY
PRESS
ARM indicator extinguishes
B. Disarming after alarm, with all zones ready: If
the zone that alarmed in the armed state is back
to normal the disarming operation will progress
as shown:
PRESS
RESULTANT DISPLAY
CODE
READY
READY MEMORY
ARM indicator extinguishes.
To read the alarm memory, refer to Chapter 3.
The "MEMORY" message will disappear only
upon re-arming the system.
C. Disarming after an alarm, with one zone still
disturbed: If the zone that alarmed in the armed
state is still disturbed the disarming operation will
progress as shown:
PRESS
RESULTANT DISPLAY
CODE
NOT READY HH:MM
NOT READY MEMORY
ARM indicator extinguishes
To read the alarm memory, refer to Chapter 3.
The "MEMORY" message will disappear only
when you rearm the system.
If you do not know how to return the disturbed
zone to normal, consult your installer.
D. Disarming with the system in a state of
trouble: If trouble is detected in the armed
state, the TROUBLE indicator on the front panel
will light and the disarming operation will
progress as shown:
PRESS
RESULTANT DISPLAY
CODE
READY HH:MM
READY TROUBLE
RESULTANT DISPLAY
CODE
_ _ _ _
READY
HH:MM
_ _ _ _
HH:MM
(alternating)
_ _ _ _
(alternating)
_ _ _ _
(alternating)
9