Weekly Maintenance; Periodic Test - Visonic PowerMax10 User Manual

Fully supervised wireless alarm control system
Table of Contents

Advertisement

6. Weekly Maintenance

Periodic Test

The components of your security system are designed to be maintenance-free as much as possible.
Nevertheless, it is mandatory to perform a "walk-test" at least once a week and after an alarm event to verify that
all system detectors function properly. Proceed as described in this section and if there is any problem, notify
your installer at once.
The periodic test is an indispensable operation by which you verify that all sirens/devices function properly,
without disturbing the neighbors with loud sirens. The test must be performed at least once a week, and
should include all sirens/devices in all zones.
Before performing the periodic test, all the sirens/devices must be in normal state. Normal state is achieved
when no motion is made for at least 2 minutes.
Note: During the test period, 24-hour zones will not cause an alarm if violated, but a fire zone will function
normally.
Carefully read the section titled "Additional Information" according to the indicated references
at end of this section.
A. To Enter the Periodic Test Menu
a) Make sure the system is disarmed and then press the
button repeatedly until the display reads "PERIODIC TEST".
b) When the display reads "PERIODIC TEST", press
The screen will now prompt you to enter your user code.
Enter your User Code and then press
B. To Periodic Test a Siren
The display now reads [SIRENS TEST].
Press
I
OK
.
The display now reads [SIREN N]. This indicates the number of enrolled
sirens in the control panel that have not been tested.
The siren will sound for 3 seconds after which the PowerMax system will
automatically repeat the procedure for the next siren enrolled in the
5
system.
When all the sirens have been tested, the display reads [SIREN TESTS
END].
D-302757
WEEKLY MAINTENANCE
I
OK
2
3
.
I
OK
4
1
.
ENTER CODE: XXXX
SIREN TESTS END
1
etc – see table
READY 00:00
or
PERIODIC TEST
I
OK
CODE
I
OK
SIRENS TEST
I
OK
SIREN N
37