PowerMaxComplete Panel Quick Guide Fully Supervised Wireless Alarm Control System 1. INTRODUCTION The system configuration is shown in figure 1. Welcome to PowerMaxComplete wireless alarm system. This guide provides step by step information that will help you to easily install and run the system and to perform basic configuration changes.
2. BACK-UP BATTERY INSERTION Front unit Battery cable Figure 2 - Battery Insertion 3. MOUNTING ON A WALL Back unit Release Mark 4 drilling points on mounting surface screws Fasten the back unit with 4 screws Drill 4 holes and insert wall anchors Figure 3 - Mounting on a Wall D-302887...
Page 3
4. WIRING PHONE WIRING IN NORTH AMERICA 8-POSITION RJ-31X JACK RJ-31X PLUG GRAY BROWN LINE HOUSE FROM RJ-31X PHONES GREEN STREET GRAY RJ-31X BROWN CORD Note: For whole house line seizure with DSL service present on the phone line, you must install a filter. It is suggested to use the DSL alarm filter model manufactured by Excelsus Technologies, or equivalent.
5. CONTROLS AND INDICATORS INDICATORS DISPLAY POWER CHIME TROUBLE NEXT SHOW/OK Press both for panic EMERGENCY FIRE (Hold alarm (Hold for 2 sec.) for 2 sec.) VOLUME UP (*) ARMING “AWAY” RECORD MESSAGE (*) PGM OUTPUT ON ARMING “HOME” VOLUME DOWN (*) PLAY MESSAGE (*) PGM OUTPUT OFF DISARMING...
Page 5
7. DEFINING ZONE TYPE, NAME, CHIME ZONES & PARTITION You can assign a type and name to each of the system's wireless & wired zones. Action(s) Resultant Display INSTALLER MODE Press 3 times Entering ENTER CODE - - - - Press installer menu...
Page 6
9. DEFINING EXIT DELAY Action(s) Resultant Display Enter into installer menu (see par. 8) 4. DEFINE PANEL Press 3 times 01: ENTRY DELAY 1 Press 03: EXIT DELAY Press 2 times EXIT DELAY 60 S Press Select delay with 03: EXIT DELAY and press * The default EXIT DELAY time is 60 S.
Page 7
11. SETUP FOR GPRS/BB – NO PHONE LINE (STEP 1) DO NOT make any program changes in “DEFINE COM” other than those shown on this instructions unless necessary. Notes: 1. Before continuing, remove power (AC and battery) and install a SIM card provisioned for GPRS data service. 2.
Page 8
12. SETUP FOR C.S. REPORTING – NO PHONE LINE (STEP 2) Action(s) Resultant Display INSTALLER MODE Press 3 times ENTER CODE once Press Enter installer code 1. NEW INST CODE (9999 by default) Press 4 times 5. DEFINE COMM. once 1:PSTN/GSM Press twice...
6 times 10.DIAGNOSTICS once Press WL SENSORS TEST 3 times Press GPRS CONN. TEST once Press PLEASE WAIT... NOTE: PANEL RSSI MUST BE “GOOD” OR “STRONG” (NOT “POOR”) VISONIC HAS EXTERNAL GSM ANTENNAS AVAILABLE (IN 10' OR 20' LENGTHS ) D-302887...
MESSAGES THAT MAY BE REPORTED TO INSTALLER AFTER TEST: LCD MESSAGE DESCRIPTION Unit is Ok GSM (Global System for Mobile Communications) / GPRS (General Packet Radio Service) is working properly GSM Com. Loss RS-232 communication with modem failed Pin Code Failure Missing or wrong PIN Code.
Page 11
16. PSTN REPORTING TO CENTRAL STATION Action(s) Resultant Display INSTALLER MODE Press 3 times ENTER CODE once Press Enter installer code 1. NEW INST CODE (9999 by default) Press 4 times 5. DEFINE COMM. once Press 1:PSTN/GSM twice Press 3:C.S. REPORTING once Press REPORT EVENTS...
Page 12
VISONIC GmbH (D-A-CH): KIRCHFELDSTR. 118, D-40215 DÜSSELDORF, TEL.: +49 (0)211 600696-0, FAX: +49 (0)211 600696-19 VISONIC IBERICA: ISLA DE PALMA, 32 NAVE 7, POLÍGONO INDUSTRIAL NORTE, 28700 SAN SEBASTIÁN DE LOS REYES, (MADRID), ESPAÑA. TEL (34) 91659-3120, FAX (34) 91663-8468. www.visonic-iberica.es INTERNET: www.visonic.com...