A4. Communication

Communication
Built-in Modem
Type of SPT (IP and cellular
modules) to CIE (control
panel) interconnections
STP Substitution Security
Information Security
Data Transfer to Local
Computer
Report Destinations
Reporting Format Options
Pulse Rate
Message to Private Phones
Ring Detection
Notes:
1.
After all trouble messages have been reviewed and if a SIM card is installed in the panel, the KP-250
keypad displays the following indications:
Cell signal strength: indicated as CELL RSSI STRONG / CELL RSSI GOOD / CELL RSSI POOR.
Network Type: indicates the type of network the cellular modem is registered to. Represented by two
characters, for example 2G or 3G.
Cellular provider: indicates the name of the cellular provider, which the cellular modem is registered
to. Represented by 13 characters, for example Orange.
2.
If a PIR camera is enrolled in the system, the control panel will read GPRS initialize to indicate that
the modem is undergoing initialization. This message appears at the end of all trouble messages and
immediately following the cellular signal strength indication (if a SIM card is installed). The trouble
indications (illuminated TROUBLE indicator and flashing TRBL message) are cleared once you
eliminate the cause of trouble. The table below describes the system faults and respective corrective
actions. If you do not know how to correct a trouble situation, report it to your installer and seek his
advice.
CELL NET FAIL
COMM. FAILURE
3.
For user programming features and information about entering an invalid user code refer to Chapter 6
sections A1 and A2.
4.
PowerMaster-33 system allows you to authorize up to 48 people to arm and disarm the system by
providing each with a unique 4 digit personal security code (code 0000 is not allowed, minimum
number of variations of PIN codes for each user - 10000 for logical keys), and assigning them with
different security levels and functionalities. For more information refer to Chapter 6, section B.4 of the
KP-250 PG2 guide.
5.
Up to 1000 events are stored in the event log that can be reviewed via the Remote Programmer PC
software application or by remote PowerManage server.
D-306917
PowerMaster-33 G2 Installer's Guide
PSTN; cellular; IP
300 baud, Bell 103 protocol
Serial UART interfaces
The control Panel has a unique ID used for enrolment to the server that burns during
production process. The server has a special procedure that the operator uses to deliver an
encrypted message with the ID to the panel.
Keep alive messages are protected with TLS protocol that prevents the transmitted data
from being read, and replaces the server name/IP (Power Manage). Events reporting and
tunneling with the ATS protect AES 128 encryption.
Via RS232 serial port
2 Monitoring Stations, 4 private telephones
SIA, Contact ID, Scancom, SIA IP, Visonic PowerNet.
10, 20, 33 and 40 pps – programmable
Tone or voice, SMS
The unit does not support ring detection without DC voltage present on the telephone lines
Fault
Meaning
The cellular communicator is not able to connect to
the cellular network
A message could not be sent to the monitoring
station or to a private telephone (or a message was
sent but was not acknowledged)