A4. Communication

Communication
Built-in Modem
Data Transfer to Local Computer
Report Destinations
Reporting Format Options
Pulse Rate
Message to Private Phones
Ring Detection

A5. Physical Properties

Operating Temp. Range
Storage Temp. Range
Humidity
Size (WxHxD)
Weight
Color

A6. Peripherals and Accessory Devices

Modules
Additional wireless devices
Wireless Devices and peripherals
22
(1) The external devices must be connected between 12V and ground. The current
for each specified backup period can be drawn from the batteries with the
internal GSM and the proximity reader connected to the PowerMaster-33 G2.
(2) 7.2V 1300 mAh, rechargeable NiMH battery pack, p/n 130AAH6BMX,
manufactured by GP or p/n LTT-AA1300LSDX6B, manufactured by LTT.
(3) 9.6V 1800 mAh, rechargeable NiMH battery pack, p/n GP180AAH8BMX,
manufactured by GP or p/n LTT-AA1800LSDX8B, manufactured by LTT.
(4) 9.6V 2200 mAh, rechargeable NiMH battery pack p/n 220AAH8BMX,
manufactured by GP or p/n LTT-AA2200LSDX8B, manufactured by LTT.
Caution! Risk of explosion if battery is replaced by an incorrect type. Dispose of
used batteries according to the manufacturer's instructions.
Notes:
1. For compliance with CE standards the battery backup period must be at least 12 hours
2. For compliance with UL standards the battery backup period must be at least 24 hours
80 % ( 30 Hrs) for all battery types
See "Backup Battery Options" table above
NA
36* mA max.
450* mA max @ 12.5 VDC when powered by AC/DC (10.5 VDC when in standby mode)
450* mA max @ 12.5 VDC when powered by AC/DC (10.5 VDC when in standby mode)
*
Total PowerMaster-33 G2 output current (of INT & EXT sirens, PGM output and
detectors) cannot exceed 550 mA.
Current sink to control panel GND 100 mA max.
Max. external DC voltage +15 VDC
All outputs are protected (automatic reset fuse)
PSTN; GSM; GPRS; IP
300 baud, Bell 103 protocol
Via RS232 serial port
2 Monitoring Stations, 4 private telephones
SIA, Contact ID, Scancom, SIA IP, Visonic PowerNet.
10, 20, 33 and 40 pps - programmable
Tone or voice
The unit does not support ring detection without DC voltage present on the telephone lines
14°F to 120°F (-10°C to 49°C)
-4°F to 140°F (-20°C to 60°C)
85% relative humidity, @ 30°C (86°F)
266 x 201 x 46 mm (10-7/16 x 7-7/8 x 1-13/16 in.)
1.44Kg (3.2 pounds) (with battery)
White
GSM/GPRS, IP
64 detectors, 32 keyfobs, 32 keypads (10 KP-250 PG2), 8 sirens, 4 repeaters , 32
proximity tags
Magnetic Contact: MC-302 PG2, MC-302E PG2, MC-302EL PG2, MC-302V PG2
Motion Detectors: Next PG2; Next K9 PG2, TOWER-32AM PG2, TOWER-32AM
K9 PG2, TOWER-30AM PG2, TOWER-30AM K9 PG2, TOWER-20 PG2, TOWER-
CAM PG2, CLIP PG2
PIR Camera Detectors: Next CAM PG2; Next CAM-K9 PG2
Smoke Detector: SMD-426 PG2, SMD-427 PG2
GSM Module: GSM-350 PG2
Keyfob: KF-234 PG2, KF-235 PG2
Keypad: KP-140 PG2/KP-141 PG2 (with proximity tag), KP-160 PG2, KP-250 PG2
Indoor Siren: SR-720 PG2
Outdoor Sirens: SR-730 PG2, SR-740 PG2, SR-740 HEX PG2
Repeater: RP-600 PG2
Gas: GSD-441 PG2, GSD-442 PG2
Glass-break: GB-501 PG2
Temperature: TMD-560 PG2
Flood: FLD-550 PG2
Shock: SD-304 PG2
D-304267