Scenario 4: Rollback to Previous Version of Switch Software
Later that year, an upgraded image file is released from Alcatel-Lucent. The network administrator loads
the new file via FTP to the working directory of the switch and reboots the switch from the working direc-
tory. Since the switch is specifically booted from the working directory, the switch is running from the
working directory.
After the reboot loads the new image file from the working directory, it is discovered that the image file
was corrupted during the FTP transfer. Rather than having a disabled switch, the network administrator
can reboot the switch from the certified directory (which has the previous, more reliable version of the
ENI image file) and wait for a new version of the image. In the meantime, the administrator's switch is
still functioning.
This is illustrated below:
R
W
C
1. The new file is
installed in the
working directory.
OmniSwitch AOS Release 6 Switch Management Guide
R
W
C
2. The new file is
loaded via a
reboot from the
working direc-
tory. The switch is
running from the
working directory.
Switch Rolls Back to Previous File Version
July 2010
R
W
C
3. The file is cor-
rupted and does
not boot correctly.
CMM Files
R
W
C
4. Switch reboots
from certified
directory by using
the old file. Since
the working and
certified directo-
ries are not the
same, it will be
running from the
certified directory.