Alcatel-Lucent OmniSwitch AOS Release 6 Manual page 100

Omniswitch series
Table of Contents

Advertisement

SNMP Overview
No. Trap Name
15
healthMonDeviceTrap
healthMonRxStatus—Rx threshold status indicating if threshold was crossed or no change.
healthMonRxTxStatus— RxTx threshold status indicating if threshold was crossed or no change.
healthMonMemoryStatus—Memory threshold status indicating if threshold was crossed or no change.
healthMonCpuStatus—CPU threshold status indicating if threshold was crossed or no change.
healthMonCmmTempStatus—CMM temperature threshold status indicating if threshold was crossed or no
change.
healthMonCmmCpuTempStatus—CMM CPU temperature threshold status indicating if threshold was
crossed or no change.
16
healthMonModuleTrap
healthModuleSlot—The (one-based) front slot number within the chassis.
healthMonRxStatus—Rx threshold status indicating if threshold was crossed or no change.
healthMonRxTxStatus—RxTx threshold status indicating if threshold was crossed or no change.
healthMonMemoryStatus—Memory threshold status indicating if threshold was crossed or no change.
healthMonCpuStatus—CPU threshold status indicating if threshold was crossed or no change.
17
healthMonPortTrap
healthPortSlot—The physical slot number for this port.
healthPortIF—The on-board interface number.
healthMonRxStatus—Rx threshold status indicating if threshold was crossed or no change.
healthMonRxTxStatus—RxTx threshold status indicating if threshold was crossed or no change.
page 3-14
Objects
Family
healthMonRx-
health
Status
healthMonRx-
TxStatus
healthMon-
MemorySta-
tus
healthMonC-
puStatus
healthMonCm-
mTempStatus
healthMonCm-
mCpuTemp-
Status
healthModule-
health
Slot
healthMonRx-
Status
healthMonRx-
TxStatus
healthMon-
MemorySta-
tus
healthMonC-
puStatus
healthPortSlot
health
healthPortIF
healthMonRx-
Status
healthMonRx-
TxStatus
OmniSwitch AOS Release 6 Switch Management Guide
Using SNMP
Description
Indicates a device-level threshold
was crossed.
Indicates a module-level thresh-
old was crossed.
Indicates a port-level threshold
was crossed.
July 2010