Agilent N9377A 16-Channel Dual-Load Load Card Specifications - Agilent Technologies E6198B User Manual

Functional test system switch/load unit
Table of Contents

Advertisement

A
Switch/Load Unit And Card Specifications

Agilent N9377A 16-Channel Dual-Load Load Card Specifications

Parameter
Switch topology
Path resistance from power bus to load card
connect
Load path relay operate/release time
Peak voltage to Earth
Load carry/switching current:
Load carry peak current
Load switching power
Load switching voltage
Minimum permissible load
Basic current sense accuracy with standard 0.05W
sense resistor
Basic current sense accuracy with differential
amplifier engaged (Vcm=0V)
Basic current sense accuracy with differential
amplifier engaged (Vcm=16V)
Isense differential amplifier 3 dB bandwidth
Isense differential amplifier slew rate
Maximum Current Consumption
A-8
Specification
16 channels with 2 loads per channel, off-board loads
0.4
maximum
Exclusive of load, with standard 0.05
and 10 A slo-blo fuse installed. (5
<1A).
10/5 msec maximum, 30 cps max
60 V continuous
500 V maximum transient, non-switching (decays to
<60V in 200mS)
7.5 A maximum non-switching, continuous
15 A max., non-switching (<100 msec, <2% duty cycle)
150 Watts maximum, resistive load
60 V maximum
10 mA, 5 V
0.1% maximum
0.2% + 30mA
0.2% + 100mA
500 kHz typical
40 A/uS typical
0.5 A at 5 V
1 A at 12 V