Register Definitions
B-18
shorted to COM, NO is open. The power buses selected depend
upon how the card is configured by the user. Writing to this
register starts the armature relay timer.
Bit
7
Purpose
K55
CH 8
Setting
state
• Write Only
• State: 1 = NO shorted to COM, NC open; 0 = NC shorted to
COM, NO open
• Power On/Reset State = 0
Power Select 9-16 (W) Base + 7
This register controls the Pull Up/Down Power Select armature
relays for channels 9-16. These relays are Form C and the
register uses positive logic: 1 = NO shorted to COM, NC is open;
0 = NC shorted to COM, NO is open. The power buses selected
depend upon how the card is configured by the user. Writing to
this register starts the armature relay timer.
Bit
7
6
Purpose
K71
K69
CH 16
CH 15
Setting
state
state
• Write Only
• State: 1 = NO shorted to COM, NC open; 0 = NC shorted to
COM, NO open
• Power On/Reset State = 0
6
5
4
K53
K51
K49
K47
CH 7
CH 6
CH 5
CH 4
state
state
state
state
h
5
4
3
K67
K65
K63
CH 14
CH 13
CH 12
state
state
state
E6198B Switch/Load Unit User Manual
3
2
1
0
K45
K43
K41
CH 3
CH 2
CH 1
state
state
state
2
1
K61
K59
K57
CH 11
CH 10
CH 9
state
state
state
0