Figure 5-5 LEM Current Transducer

Installing a LEM Current Transducer

C A U T I O N
E6198B Switch/Load Unit User Manual
Figure 5-6
shows the component location of the current-sense
section of the first two channels on the load card. The location
of the components listed in
load card's printed circuit board. Installing a current transducer
involves both elements of a channel pair. For example, if the
LEM module were to be installed across channels 1-2:
1
Remove the 0.05 current-sense resistor (R1).
The current-sense resistor must be removed from the
Agilent E6175A PC board.
2
Install the LEM module.
3
Install the measuring resistor, R2 (preferably a 100 , 0.1%
resistor).
4
Install the shorting jumper from R2 to ground, TP41 to
TP42.