Mylex Global Array Manager Installation Manual And User's Manual page 174

Hide thumbs Also See for Global Array Manager:
Table of Contents

Advertisement

Overview
ID
Severity
405
3
414
3
415
3
418
2
427
2
428
0
429
4
430
4
A-22
Table A-2. GAM Events for PCI Controllers
Description
Battery Removed.
Soft ECC error
Corrected.
Physical ECC error
Corrected.
BBU out of service.
Mirror Race
recovery failed.
Mirror Race on
critical logical drive.
Controller
connected to
cluster.
Controller
disconnected from
cluster.
Details
Battery physically
removed.
Faulty Memory
Module.
Faulty Memory
Module.
BBU will not be able
to power the cache if
AC power fails.
Firmware will switch
WriteBack logical
drives to
WriteThrough.
Some physical
devices may have
failed.
Logical device is
critical.
One or more
controllers detected
during scan and
entered nexus with
those controllers.
All other controllers
in cluster are
inaccessible due to
controller powered
off or controller
failure or cable
failure.
GAM Client User's Guide
Actions
Reinstall the
battery.
Replace Memory
Module.
Replace Memory
Module.
Replace BBU.
Run consistency
check and
restore
consistency.
Replace failed
physical disk and
rebuild.
None.
If this was an
unexpected
event, refer to
service manual
and correct the
failure.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Global Array Manager and is the answer not in the manual?

Questions and answers

Table of Contents