ID
Severity
158
1
159
2
160
2
161
2
162
4
256
1
Manual No. SA67-0049-01
Table A-2. GAM Events for PCI Controllers
Description
Attempt to read
data from block that
is marked in Bad
Data Table.
Data for Disk Block
has been lost due to
Logical Drive
problem.
Temporary-Offline
RAID5/RAID3 array
is available to the
user again with the
possibility of data
loss in the array.
Temporary-Offline
RAID0+1/RAID1/
RAID0/JBOD array
is available to the
user again.
An standby rebuild
has started on
logical drive.
Fan Failure.
Details
Attempt to read from
block that is already
marked bad in Bad
Data Table. Potential
data loss.
Data retained in
RAID Cache for a
Write-back Logical
Drive cannot be
stored to the physical
medium because of
Logical Drive
problem. The Logical
Drive problem could
be because of
multiple physical
medium error or
multiple physical
devices offline or
other reasons.
Temporary-Offline
state caused
because of transient
errors in physical
drives.
Temporary-Offline
state caused
because of transient
errors in physical
drives.
A physical disk failed
and a spare device
was available.
Cable connection is
broken. Fan failure.
Event Information
Actions
Restore data
from a back up.
Insure that all the
Physical Drives
related to the
Logical Drive,
disk channel,
enclosure or
cabling are
functional and
accessible.
Repair or
replace them if
necessary.
Verify data from
backup.
No action.
None.
Replace fan.
A-15
Need help?
Do you have a question about the Global Array Manager and is the answer not in the manual?
Questions and answers