ID
Severity
32
1
33
1
34
1
35
1
36
1
37
1
38
1
39
1
40
1
Manual No. SA67-0049-01
Table A-2. GAM Events for PCI Controllers
Description
Initialization
cancelled.
A physical disk
failed because write
recovery failed.
A physical disk
failed because
SCSI bus reset
failed.
A physical disk
failed because
double check
condition occured.
A physical disk
failed because
device is missing.
A physical disk
failed because of
gross error on SCSI
processor.
A physical disk
failed because of
bad tag from the
device.
A physical disk
failed because
command to the
device timed out.
A physical disk
failed because of
the system reset.
Details
User cancelled the
operation.
Write recovery
process failed.
SCSI bus reset
failed.
Double check
condition occurred.
Access to the
physical disk failed.
Gross error occurred
to the on board SCSI
processor.
The device
responded with an
invalid tag.
SCSI command
timed out on the
device.
System reset
occured.
Event Information
Actions
Physical disk
must be
initialized again
or the Physical
disk cannot be
used.
Replace physical
disk and rebuild
it.
Replace physical
disk and rebuild
it.
Replace physical
disk and rebuild
it.
Replace physical
disk and rebuild
it.
Replace physical
disk and rebuild
it.
Replace physical
disk and rebuild
it.
Replace physical
disk and rebuild
it.
Replace physical
disk and rebuild
it.
A-7
Need help?
Do you have a question about the Global Array Manager and is the answer not in the manual?