ID
Severity
328
4
329
4
330
3
331
4
332
2
384
4
385
2
Manual No. SA67-0049-01
Table A-2. GAM Events for PCI Controllers
Description
Normal temperature
has been restored.
Temperature
sensor is not
present.
Enclosure access
critical.
Enclosure access
has been restored.
Enclosure access is
offline.
Array management
server software
started
successfully.
Write back error.
Details
Faulty fan has been
replaced. Room
temperature was
reduced.
Enclosure
management
connection is broken.
Management
hardware failure.
Sensor is not
present.
Enclosure
management
connection is broken.
Management
hardware failure.
Enclosure has been
fixed or replaced.
Enclosure
management
connection is broken.
Management
hardware failure.
The server system
(or array
management utility
server) started.
Data cache write
failed.
Event Information
Actions
None.
Refer to the
enclosure
manufacturer's
service manual.
Refer to the
enclosure
manufacturer's
service manual.
None.
Refer to the
enclosure
manufacturer's
service manual.
If you did not
expect a system
reboot,
investigate.
The data may
have been lost.
Restore the data
from a backup.
A-19
Need help?
Do you have a question about the Global Array Manager and is the answer not in the manual?
Questions and answers