Overview
ID
Severity
41
1
42
1
43
1
44
1
45
1
46
1
47
1
A-8
Table A-2. GAM Events for PCI Controllers
Description
A physical disk
failed because of
busy status or parity
error.
A physical disk set
to failed state by
host.
A physical disk
failed because
access to the
device met with a
selection time out.
A physical disk
failed because of a
sequence error in
the SCSI bus phase
handling.
A Physical disk
failed because
device returned an
unknown status.
A Physical disk
failed because
device is not ready.
A Physical disk
failed because
device was not
found on start up.
Details
The device returned
busy status. The
SCSI transaction
with the device met
with parity error.
Command from host
set the Physical disk
to failed state.
Device disconnected
or powered off. Bad
device.
Physical disk failure.
Bad Physical disk or
incompatible device.
Device not spinning,
just turned bad.
Power to the device
failed.
Device not
connected. Device
not responding.
Clear configuration
suspend mode
command was
invoked.
GAM Client User's Guide
Actions
Replace physical
disk and rebuild
it.
Replace physical
disk and rebuild
it.
Replace physical
disk and rebuild
it. Check power
and cabling.
Replace physical
disk and rebuild
it.
Replace
Physical disk or
the device and
rebuild it.
Replace
Physical disk
and rebuild it.
Check power
and rebuild
device.
Check setup.
Check the
startup option
parameters on
the system.