Overview
ID
Severity
386
3
388
0
389
3
390
4
391
0
392
4
A-20
Table A-2. GAM Events for PCI Controllers
Description
Internal log
structures getting
full, PLEASE
SHUTDOWN AND
RESET THE
SYSTEM IN THE
NEAR FUTURE.
Controller is dead.
System is
disconnecting from
this controller.
Controller has been
reset.
Controller is found.
Controller is gone.
System is
disconnecting from
this controller.
Battery Present
Details
Too many
configuration
changes occurred
since the last boot.
Hardware failure.
Controller received a
reset command.
New controller has
been installed.
Management
software has
restarted.
System has
rebooted.
Controller has been
powered off or has
been reset.
Controller has been
removed from the
system.
A battery module has
been detected and is
now operational.
GAM Client User's Guide
Actions
Reboot the
system by power
cycling when
ever convenient.
Contact your
service
representative.
If this was an
unexpected
event, refer to
the enclosure
manufacturer's
service manual.
None.
None.
None.
Need help?
Do you have a question about the Global Array Manager and is the answer not in the manual?