Mylex Global Array Manager Installation Manual And User's Manual page 170

Hide thumbs Also See for Global Array Manager:
Table of Contents

Advertisement

Overview
ID
Severity
306
4
320
1
321
4
322
4
323
1
324
4
325
4
326
2
327
3
A-18
Table A-2. GAM Events for PCI Controllers
Description
Storage Works
enclosure reported
normal state.
Fan failure.
Fan has been
restored.
Fan is not present.
Power supply
failure.
Power supply has
been restored.
Power supply is not
present.
Temperature is over
safe limit. Failure
imminent.
Temperature is
above working limit.
Details
Problem has been
rectified.
Cable connection
broken. Fan failure.
Faulty fan has been
replaced. Cable is
connected properly.
Enclosure
Management
Connection is
broken. Management
hardware failure. Fan
is not present.
Cable connection is
broken. Power
supply failure.
Faulty power supply
has been replaced.
Management
connection is broken.
Management
hardware is bad.
Power supply is not
present.
Room temperature is
too high. Fan failure.
Sensor failure.
Room temperature is
too high. Fan failure.
GAM Client User's Guide
Actions
None.
Replace fan.
None.
Refer to the
enclosure
manufacturer's
service manual.
Replace the
power supply.
None.
Refer to the
enclosure
manufacturer's
service manual.
Turn off the
system and
allow it to cool
down. Adjust the
room
temperature.
Turn off the
system. Adjust
the room
temperature.
Replace fan.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Global Array Manager and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Table of Contents