This section lists event messages from the command line interface and SANsurfer
Switch Manager in message ID sequence by the following severity levels:
You can look up a message by its message ID or by searching for the message
text. If the message you are looking for does not appear in this section, contact
your authorized maintenance provider.
3.1

Alarm Events

(A1000.000F) (The switch is canceling the hotreset - try again later)
Meaning:
Action:
(A1000.001D) (Hotreset failed and the switch must be reset normally)
Meaning:
Action:
(A1000.001E) (Hotreset failed and the switch is being reset)
Meaning:
Action:
59060-01 B

Event Messages

Alarm Events

Critical Events

Warning Events
Informative Events
You cannot move forward with the hot reset. All applications and
switch resources are backing out of the procedure and returning to
normal operation.
Ensure that the fabric is stable and that no changes are being
made to switch configurations or connections and try again.
The hot reset has failed and left the switch in an indeterminate
state.
Reset the switch.
There was a failure during the hotreset process, the switch is being
reset normally.
None.