3 – Event Messages
Alarm Events
(A2000.0002) (Pwr2 failure - ALARM SET)
Meaning:
Action:
(A2001.0001) (Pwr2 was installed - ALARM CLEARED)
Meaning:
Action:
(A2002.0001) (
fan_number
Meaning:
Action:
(A2002.0002) (Fan
fan_number
Meaning:
Action:
(A2002.0003) (Fan flow mismatch - ALARM SET)
Meaning:
Action:
(A2003.0003) (Fan flow match - ALARM CLEARED)
Meaning:
Action:
(A3000.0001) (Temp overheat,
Meaning:
Action:
(A3000.0002) (Temp sensor
Meaning:
Action:
(A3001.0001) (Temp overwarm,
Meaning:
Action:
3-16
Power supply #2 was has failed or was removed from the switch.
Contact your authorized maintenance provider.
Power supply #2 was installed.
None.
was removed)
A field replaceable fan was removed from the switch.
Reinstall the fan.
failure - ALARM SET)
A cooling fan has failed.
Replace the fan if it is a field replaceable unit. Otherwise, contact
your authorized maintenance provider.
The switch has two cooling fans with opposite air flow directions.
Replace one of the fans with another fan with the correct air flow
direction.
The opposing fan air flow condition has been corrected.
None.
sensor reads
sensor_name
The chassis temperature has reached a failure threshold.
Check air flow, fan operation, and ambient temperature. If the
problem cannot be corrected, power down the switch.
on blade
sensor_name
The chassis temperature has reached a failure threshold.
Check air flow, fan operation, and ambient temperature. If the
problem cannot be corrected, power down the switch.
sensor reads
sensor_name
The chassis temperature has reached a warning threshold.
Check air flow, fan operation, and ambient temperature.
C - ALARM SET)
value
reads
slot_number
value
C - ALARM SET)
value
A
C - ALARM SET)
59060-01 B