Host-To-Switcher Instructions; Switcher Error Responses; Using The Command/Response Table - Extron electronics ISM 482 User Manual

Integration scaling matrix switcher
Hide thumbs Also See for ISM 482:
Table of Contents

Advertisement

Aut
X3
The Auto Presets feature has been turned on or off from the front panel for all tie
creations.
1Enh
X19
The enhanced mode feature has been turned on or off from the front panel for
S-video or composite video that is tied to one or both outputs.
status for the two outputs. The leading "1" is meaningless.
Reconfig
X2
The input selected for the
feature or a user preset.

Host-to-Switcher Instructions

The switcher accepts SIS commands through its RS-232 port and/or its Ethernet
port. SIS commands consist of one or more characters per command field. They do
not require any special characters to begin or end the command character sequence.
Each switcher response to an SIS command ends with a carriage return and a line
feed (CR/LF =
is one or more characters.

Switcher error responses

When the switcher receives an SIS command and determines that it is valid, it
performs the command and sends a response to the host device. If the switcher is
unable to perform the command because the command is invalid or contains
invalid parameters, the switcher returns an error response to the host. The error
response codes are:
E01 — Invalid input channel number (too large)
E10 — Invalid command
E11 — Invalid preset number (zero or too large)
E12 — Invalid output number (zero or too large)
E13 — Invalid value (out of range)

Using the command/response table

The command/response table begins on the next page. Except for the gain and
attenuation settings and the filter settings, upper or lower case letters are acceptable
in the command field. Command and response examples are shown throughout
the table.
The table below shows the hexadecimal equivalent of each ASCII command.
ASCII to HEX Conversion Table
Space
is the on/off status.
X3
output has been adjusted using the Auto Image
X2
), which signals the end of the response character string. A string
With the exception of the audio gain and attenuation (G and g) and horizontal
Integration Scaling Matrix Switcher • Programmer's Guide
is the on/off
X19
and vertical filtering (D and d)
commands, the SIS commands
are not case sensitive.
4-7

Advertisement

Table of Contents
loading

Table of Contents