Control Variables in CustomDSO

The simplest way to select variables for use in CustomDSO is to use LeCroy's X-Stream Browser.

LABNOTEBOOK

Introduction to LabNotebook

LeCroy's LabNotebook feature extends the documentation ca
an annotated notebook entry containing all displayed wa
annotation. The notebook entry can then be co
mailed. You can also use the default report layout or configu
logo in the header.
Notebook entries are stored in an internal database and
waveform data, LabNotebook also stores your panel setup
capability to back up the database to external media.
The Flashback feature allows you to recall the state of
and the DSO setup, so that you can make additional mea
correct notebook entry to recall.
You can choose which notebook to use for your entrie
os
cilloscope is shared among several users, for example, or used for different projects, the data can be kept
se
parately. Similarly, hardcopy reports can be stored in different folders.

Preferences

You should set your preferences before creating noteboo

Miscellaneous Settings

Hardcopy Setup

E-mail Setup

WRXi-OM-E Rev C
nverted to hardcopy format - pdf, rtf, or html - and printed or e-
You can elect to name note
the top box unchecked. Check the box if you want the opportunity to rename the
notebook entry as soon as it is created.
Check the middle box if you want to be able to annotate a notebook entry as soon
as it is created.
Check the last box if you want to generate a notebook entry by simply touching the
Hardcopy (Print) front panel button
other configuration for this
Check the Use Print Colors checkbox to place your waveforms on a white
background in the notebo
the hardcopy report.
Touch inside Hardcopy Area to determine how much of the screen image to
in
clude in the report: grid area only, grid area plus dialog, whole screen.
You can e-mail just the pdf or html report; or, you can include additional files: trace
data (.trc) for each waveform in the report, a screen dump, a oscilloscope setup
file, and an xml report record. Touch the checkbox to enable the extra report
segments.
Touch the C nfigure E-Mail button to set the recipient address and server
o
information.
pabilities of your oscilloscope. It allows you to create
veforms, the setup of the DSO, and user-supplied
re your own, and even substitute your own company
are available for recall at any time. Besides storing the
s and parameter measurements. You have the
the DSO at a later date, including the saved waveforms
surements. A keyword filter makes it easy to find the
s, and label the notebook by project or user. If the
k entries.
boo
k entries with the default date and time by leaving
. By checking this box, you override any
button; for example, send e-mail or output to printer.
ok
entry. This will save printer ink later when you print
O
'
M
PERATOR
S
ANUAL
227