Sign In
Upload
Manuals
Brands
LeCroy Manuals
Test Equipment
WAVERUNNER 6000 SERIES
LeCroy WAVERUNNER 6000 SERIES Manuals
Manuals and User Guides for LeCroy WAVERUNNER 6000 SERIES. We have
2
LeCroy WAVERUNNER 6000 SERIES manuals available for free PDF download: Operator's Manual, Service Manual
LeCroy WAVERUNNER 6000 SERIES Operator's Manual (409 pages)
WAVERUNNER
Brand:
LeCroy
| Category:
Test Equipment
| Size: 5 MB
Table of Contents
Table of Contents
3
Introduction
16
How to Use On-Line Help
16
Type Styles
16
Instrument Help
16
Windows Help
17
Returning a Product for Service or Repair
17
Technical Support
17
Staying Up-To-Date
18
Specifications
19
Horizontal System
20
Acquisition System
21
Acquisition Modes
21
Acquisition Processing
22
Triggering System
22
Basic Triggers
22
SMART Triggers
22
SMART Triggers with Exclusion Technology
23
Automatic Setup
23
Probes
23
Color Waveform Display
23
Analog Persistence Display
24
Zoom Expansion Traces
24
Rapid Signal Processing
24
Internal Waveform Memory
24
Setup Storage
24
Interface
24
Auxiliary Input
24
Auxiliary Output
25
Math Tools (Standard)
25
Measure Tools (Standard)
26
Pass/Fail Testing
26
Master Analysis Package (XMAP)
26
Advanced Math Package (XMATH)
27
Advanced Customization Package (XDEV)
27
Intermediate Math Package (XWAV)
27
Jitter and Timing Analysis Package (JTA2)
28
Value Analysis Package (XVAP)
28
Disk Drive Measurement Package (DDM2)
29
General
29
Operator's Manual
30
Warranty and Service
30
Environmental Characteristics
30
Temperature
30
Humidity
30
Altitude
30
Random Vibration
30
Shock
30
Certifications
31
CE Declaration of Conformity
31
Warning
31
Warranty
32
Copyright
33
Safety Requirements
41
Safety Symbols and Terms
41
Operating Environment
42
Cooling Requirements
43
AC Power Source
43
Power and Ground Connections
43
On/Standby Switch
44
Calibration
44
Cleaning
44
Abnormal Conditions
45
Front Panel Controls
45
Front Panel Buttons and Knobs
45
Trigger Knobs
47
Trigger Buttons
47
Horizontal Knobs
47
Vertical Knobs
48
Channel Buttons
48
Wavepilot Control Knobs
48
Special Features Buttons
48
General Control Buttons
48
On-Screen Toolbars, Icons, and Dialog Boxes
49
Dialog Boxes
50
Alternate Access Methods
50
Mouse and Keyboard Operation
50
Tool Bar Buttons
51
Trace Descriptors
52
Trace Annotation
52
To Annotate a Waveform
53
To Turn on a Channel Trace Label
54
Screen Layout
55
Installation
57
Hardware
57
External Monitor
57
Writable CD Drive Option
58
Software
61
Checking the Scope Status
61
Default Settings
62
Wavemaster and Wavepro 7000 Series Dsos
62
DDA, SDA, and Waverunner Dsos
62
Adding a New Option
63
Restoring Software
64
Restarting the Application
64
Restarting the Operating System
64
Removable Hard Drive
64
External Monitor
66
Connecting to a Signal
68
Probus Interface
68
Auxiliary Output Signals
69
To Set up Auxiliary Output
69
Sampling Modes
70
To Select a Sampling Mode
70
Single-Shot Sampling Mode
70
Basic Capture Technique
70
Sequence Sampling Mode Working with Segments
71
To Set up Sequence Mode
72
Sequence Display Modes
73
To Display Individual Segments
74
To View Time Stamps
74
Ris Sampling Mode -- for Higher Sample Rates
75
Roll Mode
76
Vertical Settings and Channel Controls
77
Adjusting Sensitivity and Position
77
To Adjust Sensitivity
77
To Adjust the Waveform's Position
77
Coupling
77
Overload Protection
77
To Set Coupling
78
Operator's Manual
78
Probe Attenuation
78
To Set Probe Attenuation
78
Bandwidth Limit
78
To Set Bandwidth Limiting
78
Linear and (Sinx)/X Interpolation
79
To Set up Interpolation
79
Inverting Waveforms
79
Quickzoom
79
To Turn on a Zoom
79
Finding Scale
79
To Use Find Scale
79
Variable Gain
79
To Enable Variable Gain
80
Channel Deskew
80
To Set up Channel Deskew
80
Timebase and Acquisition System
81
Timebase Setup and Control
81
Dual Channel Acquisition
81
Combining of Channels
81
To Combine Channels
81
Autosetup
82
Triggering
83
Trigger Setup Considerations
83
Trigger Modes
83
Trigger Types
83
Determining Trigger Level, Slope, Source, and Coupling
84
Trigger Source
85
Level
85
Holdoff by Time or Events
86
Hold off by Time
86
Hold off by Events
87
Simple Triggers
87
Edge Trigger on Simple Signals
87
Control Edge Triggering
87
To Set up an Edge Trigger
88
Smart Triggers
91
Width Trigger
91
Glitch Trigger
92
Interval Trigger
94
Qualified Trigger
98
State Trigger
101
Dropout Trigger
102
Logic Trigger
103
Display Formats
106
Display Setup
106
Sequence Mode Display
106
Persistence Setup
107
Saturation Level
107
3-Dimensional Persistence
108
Show Last Trace
109
Persistence Time
110
Locking of Traces
110
To Set up Persistence
110
Screen Saver
111
Moving Traces from Grid to Grid
111
Zooming Waveforms
112
To Zoom a Single Channel
113
To Zoom by Touch-And-Drag
113
To Zoom Multiple Waveforms Quickly
114
Multi-Zoom
114
Xy Display
116
To Set up XY Displays
116
Save and Recall
117
Saving and Recalling Scope Settings
117
To Save Scope Settings
117
To Recall Scope Settings
117
To Recall Default Settings
117
Saving Screen Images
118
Saving and Recalling Waveforms
118
Saving Waveforms
118
Recalling Waveforms
120
Disk Utilities
120
To Delete a Single File
120
To Delete All Files in a Folder
121
To Create a Folder
121
Printing and File Management
122
Print, Plot, or Copy
122
Printing
122
To Set up the Printer
122
To Print
122
Adding Printers and Drivers
122
Changing the Default Printer
123
Managing Files
123
Hard Disk Partitions
123
Operator's Manual
124
100Base-T Ethernet Connection
124
Connecting to a Network
124
Communicating over the Network
125
Windows Setups
125
Windows Repair Disk
125
Track Views
126
Creating and Viewing a Trend
126
Creating a Track View
127
Histograms
128
Creating and Viewing a Histogram
128
To Set up a Single Parameter Histogram
128
To View Thumbnail Histograms
129
Persistence Histogram
129
Persistence Trace Range
130
Persistence Sigma
130
Histogram Parameters
130
Histogram Theory of Operation
145
DSO Process
146
Parameter Buffer
147
Capture of Parameter Events
147
Histogram Parameters (XMAP and JTA2 Options)
148
Histogram Peaks
149
Binning and Measurement Accuracy
149
Waveform Measurements
151
Measuring with Cursors
151
Cursor Measurement Icons
151
Cursors Setup
151
Quick Display
151
Full Setup
152
Overview of Parameters
152
To Turn on Parameters
152
Quick Access to Parameter Setup Dialogs
152
Status Symbols
153
Using X-Stream Browser to Obtain Status Information
154
Statistics
155
To Apply a Measure Mode
156
Measure Modes
156
Standard Vertical Parameters
156
Standard Horizontal Parameters
157
My Measure
157
Parameter Math (XMATH or XMAP Option Required)
157
Logarithmic Parameters
157
Excluded Parameters
158
Parameter Script Parameter Math
158
Param Script Vs. P Script
159
To Set up Parameter Math
160
To Set up Parameter Script Math
160
Measure Gate
161
To Set up Measure Gate
163
Help Markers
164
To Set up Help Markers
165
To Turn off Help Markers
166
To Customize a Parameter
166
From the Measure Dialog
166
From a Vertical Setup Dialog
166
From a Math Setup Dialog
167
Parameter Calculations
168
Parameters and How They Work
168
Determining Time Parameters
170
Determining Differential Time Measurements
171
Level and Slope
171
List of Parameters
172
Waveform Math
196
Introduction to Math Traces and Functions
196
Math Made Easy
196
To Set up a Math Function
196
Resampling to Deskew
197
To Resample
197
Rescaling and Assigning Units
198
To Set up Rescaling
198
Averaging Waveforms
198
Summed Vs. Continuous Averaging
198
To Set up Continuous Averaging
200
To Set up Summed Averaging
200
Enhanced Resolution
201
How the Instrument Enhances Resolution
201
To Set up Enhanced Resolution (ERES)
203
Waveform Copy
204
Waveform Sparser
204
To Set up Waveform Sparser
204
Interpolation
205
To Set up Interpolation
205
Fft
205
Why Use Fft
205
Operator's Manual
208
Improving Dynamic Range
208
Record Length
209
Fft Algorithms
209
Glossary
211
Fft Setup
214
Analysis
216
Pass/Fail Testing
216
Comparing Parameters
216
Mask Tests
217
Actions
217
Setting up Pass/Fail Testing
218
Initial Setup
218
Comparing a Single Parameter
219
Comparing Dual Parameters
220
Mask Testing
221
Utilities
223
Status
223
To Access Status Dialog
223
Remote Communication
223
To Set up Remote Communication
223
To Configure the Remote Control Assistant Event Log
224
Hardcopy
224
Printing
224
Clipboard
224
File
224
E-Mail
225
Aux Output
226
Date & Time
226
To Set Time and Date Manually
226
To Set Time and Date from the Internet
226
To Set Time and Date from Windows
226
Options
227
Preferences
227
Audible Feedback
227
Auto-Calibration
228
Offset Control
228
Delay Control
228
Performance Optimization
228
E-Mail
229
Acquisition Status
229
Service
230
Show Windows Desktop
230
Touch Screen Calibration
230
Customization
231
Customizing Your Instrument
231
Introduction
231
Solutions
231
Examples
232
What Is Excel
237
What Is Mathcad
237
What Is MATLAB
237
What Is VBS
237
What Can You Do with a Customized Instrument
239
Calling Excel from Your Instrument
240
Calling Excel Directly from the Instrument
240
How to Select a Math Function Call
241
How to Select a Parameter Function Call
241
The Excel Control Dialog
241
Entering a File Name
241
Organizing Excel Sheets
243
Setting the Vertical Scale
244
Trace Descriptors
244
Multiple Inputs and Outputs
245
Simple Excel Example 1
245
Simple Excel Example 2
249
Examples of Excel Parameter Functions
252
Examples of Excel Waveform Functions
253
Exponential Decay Time Constant Excel Parameter (Excel Example 1)
253
Gated Parameter Using Excel (Excel Example 2)
255
How Does this Work
256
Correlation Excel Waveform Function (Excel Example 3)
257
Multiple Traces on One Grid (Excel Example 4)
259
Using a Surface Plot (Excel Example 5)
262
Writing Vb Scripts
264
Types of Scripts in VBS
264
Loading and Saving Vbscripts
264
The Default Parameter Function Script: Explanatory Notes
268
Scripting with Vbscript
269
Variable Types
270
Variable Names
270
Arithmetic Operators
272
VBS Controls
274
Summary of if
276
Select Case
277
Summary of Select Case
278
While
279
For
279
Operator's Manual
278
VBS Keywords and Functions
280
Other VBS Words
282
Functions
282
Hints and Tips for Vbscripting
283
Errors
285
Error Handling
287
Speed of Execution
287
Scripting Ideas
288
Example Waveform Script
288
Example Parameter Scripts
289
Debugging Scripts
289
Horizontal Control Variables
289
Vertical Control Variables
290
List of Variables Available to Scripts
290
Communicating with Excel from a Vbscript
292
Calling Matlab from the Instrument
293
Calling MATLAB
293
How to Select a Waveform Function Call
294
The MATLAB Waveform Control Panel
295
MATLAB Waveform Function Editor -- Example
295
MATLAB Example Waveform Plot
299
How to Select a MATLAB Parameter Call
300
The MATLAB Parameter Control Panel
301
The MATLAB Parameter Editor
302
MATLAB Example Parameter Panel
303
Further Examples of MATLAB Waveform Functions
305
Creating Your Own MATLAB Function
308
Customdso
309
Introduction - What Is Customdso
309
Invoking Customdso
309
Customdso Basic Mode
310
Editing a Customdso Setup File
310
Creating a Customdso Setup File
312
Customdso Plugin Mode
312
Creating a Customdso Plugin
312
Properties of the Control and Its Objects
314
Removing a Plugin
318
First Example Plugin - Exchanging Two Traces on the Grids
318
Second Example Plugin - Log-Log FFT Plot
321
Control Variables in Customdso
324
Jta2 Option
325
Accessing Jta2
325
Timing Functions
325
Timing Parameters
326
Statistical Tools
326
How Jittertrack Works
326
Using "Clock" or "Data
326
When to Use Jittertrack
329
Jittertrack or Trend
329
Clock or Data
331
Setting up Jitter Measurements
333
Jitter Math Setup
333
Jitter Parameters Setup
333
When to Use Persistence Histograms
333
Setting up Persistence Histograms
334
Selecting the Math Function
334
Setting up the Histogram
335
How to Trace Persistence
336
An Innovative Visual and Processing Tool
336
To Set up Trace Persistence
337
Choosing a Timing Parameter
339
How to Use the Trend Tool
339
The Basic Idea
339
To Set up and Configure Trend
340
Math Setup
343
Histogram and Trend Calculation
343
Acquisition Sequence
343
Parameter Buffer
344
Parameter Events Capture
344
Zoom Traces and Segmented Waveforms
345
Histogram Peaks
345
Example
345
Binning and Measurement Accuracy
346
Dfp2 Option
349
Introduction
349
The Need
349
The Solution
349
Enhanced Solutions
350
Kinds of Filters
351
Communications Channel Filters
353
Operator's Manual
355
IIR Filters
355
Filter Setup
356
To Set up a DFP Filter
356
Multirate Filters
357
Description
357
Custom Filters
358
Custom Filter Setup
358
Example 1: Creating an FIR Filter Coefficient File Using Mathcad
358
Example 2: Creating an IIR Filter Coefficient File Using Mathcad
360
Specifications
361
Pma2 Option
362
Introduction to Pma2
362
The Tools and What They Do
362
Equipment Required
362
Deskewing Voltage and Current
363
Matching the Time Delay in Your Measurement System
363
Initial Setup
365
Clearing the Deskew Setup
369
Using Power Device Analysis
370
Setup and Configuration for Power Device Analysis
370
Initial Setup (Optional Event Trigger)
371
Initial Setup (Main Trigger)
372
Setup for Power Device Analysis
373
Power Device Analysis Measurements
375
Saturation Voltage and Dynamic On-Resistance Measurement
379
Fine DC Level Adjustment
381
Effects of Probe Compensation on Saturation Voltage Measurements
381
Example
382
Clearing the Power Device Analysis Setup
384
Measuring Device DV/Dt
384
To Access DV/Dt
385
Using Modulation Analysis
386
How Modulation Analysis Works
386
The Modulation Analysis Display
389
Configuration for Modulation Analysis
389
Setup for Modulation Analysis Measurements
390
Modulated Signal and Trigger Setup
390
Trigger Setup - the Event Trigger
391
Initial Setup - the Modulated Signal
392
Finishing the Setup and Making Modulation Measurements
392
Activating the Modulation Analysis Menu
392
Modulation Analysis Controls
393
Optimizing the Display
394
Clearing the Modulation Analysis Setup
394
Using Line Power Analysis
395
Line Power Analysis Overview
395
EN 61000-3-2, Harmonic Current Emissions
395
Configuration for Line Power Analysis
396
Setting up the Line Voltage and Current Signals
398
Activating the Line Power Analysis Menu
399
Line Harmonics Measurement
400
Using Non-Probus Probes
403
PMA2 Dialog Overview
403
Current Input Setup Menus
404
Voltage Input Setup Menus
405
Processing Web
406
To Use the Web Editor
406
Advertisement
LeCroy WAVERUNNER 6000 SERIES Service Manual (325 pages)
Color Digital Oscilloscopes
Brand:
LeCroy
| Category:
Test Equipment
| Size: 16 MB
Table of Contents
Table of Contents
3
Read this First
11
Warranty
11
Warranty and Product Support
11
Product Assistance
11
Maintenance Agreements
11
Staying up to Date
12
Service and Repair
12
How to Return a Product
12
What Comes with Your Scope
12
General Information
13
Product Assistance
13
Installation for Safe and Efficient Operation
13
Operating Environment
13
Safety Symbols
13
Power Requirements
15
Cleaning and Maintenance
15
Specifications
17
Vertical System
17
Horizontal System
17
Acquisition System
18
Acquisition Processing
18
Triggering System
18
Basic Triggers
19
SMART Triggers
19
SMART Triggers with Exclusion Technology
19
Probes
19
Color Waveform Display
20
Analog Persistence Display
20
Zoom Expansion Traces
20
Cpu
20
Internal Waveform Memory
20
Setup Storage
20
Interface
20
Auxiliary Input
21
General
21
Environmental
21
Physical Dimensions
21
Certifications
21
Warranty and Service
21
Theory of Operation
23
System Block Diagram
23
Computer
24
Operating System
24
Memory
24
Interfaces
24
Storage Devices
24
CMOS Settings
24
PCI Card
25
Display and Touch Screen
26
Touch Screen
26
Acquisition System
27
Main Card
28
JTAG Chains
29
Serial Chains
29
Controller FPGA
30
Microcontroller
30
Timebase & Trigger
31
Htb645
31
Trigger Bandwidth
31
Trigger Signal I/O
31
Tdc
31
Timebase
31
Miscellaneous Clocks
32
MST429A - Smart Trigger IC
32
Signal I/O
32
Trigger Functions
32
Main Trigger Delay
32
Qualifier Selection
32
Polarity
32
Analog Time Measure
32
Digital Time Measure
32
Trigger Frequency
33
ADC & Memory
33
Had639
33
Signal I/O
33
Adc's
33
Calibration
33
Control
34
Mam439
34
Signal I/O
34
Decimation
34
Front End
36
Hfe653
36
Power off State
37
Path
38
1MΩ /1 Path DC Coupled
39
1MΩ /10 Path DC Coupled
39
1MΩ /100 Path DC Coupled
40
1MΩ /1 Path AC Coupled
40
Other Sub Systems
41
Power Supply
41
NCO (Numerically Controlled Osc.)
41
10Ghz Clock
41
Performance Verification
43
Introduction
43
List of Tested Characteristics
43
Calibration Cycle
43
Test Equipment Required
44
Test Records
44
Turn on
44
Input Impedance
45
Channel Input Impedance
45
External Trigger Input Impedance
48
Leakage Current
49
Channel Leakage Current
49
External Trigger Leakage Current
52
Peak-Peak Noise Level
54
Gs/S 50 Ohm
54
Gs/S Channel Mode (WR6100 & WR6200 Only)
56
DC Accuracy
59
Positive 50Ω DC Accuracy
59
Negative 50Ω DC Accuracy
62
Positive 1MΩ DC Accuracy
63
Negative 1MΩ DC Accuracy
65
Offset Accuracy
67
Positive 50Ω Offset Accuracy
67
Negative 50Ω Offset Accuracy
69
Positive 1MΩ Offset Accuracy
70
Negative 1MΩ Offset Accuracy
72
Bandwidth
73
Description
73
Trigger Level
78
Description
78
Channel Trigger at 0 Division Threshold
78
Channel Trigger at +2.5 Divisions Threshold
80
Time Base Accuracy
83
Description
83
10 Ghz Clock Verification Procedure
83
Maintenance
97
Introduction
97
Safety Precautions
97
Anti-Static Precautions
97
Disassembly and Assembly Procedure
98
Disassembly Procedure
98
Removal of the Upper Cover Assembly
98
Opening of the Front Bezel
98
Removal of the Acquisition System Assembly
99
Removal of the PCI Board
100
Removal of the AGP-DVO Interface Board
100
Removal of the Processor Board
100
Removal of the Hard Disk Drive
101
Removal of the CD ROM Drive
101
Removal of the Power Supply
101
Removal of the Front Frame Assembly
102
Removal of the Front Panel Encoder Board
103
Removal of the USB Hub Board
103
Removal of the Display Inverter Board
104
Removal of the Display and Touchscreen
104
Replacing the Battery
105
Assembly Procedure
106
Installing Hardware Options
107
Software Update Procedure
107
Installing New X-Stream DSO Application Software
107
Software End User License Agreement
107
Installing Device Drivers
113
Upgrading Microcode
114
Verifying Microcode
115
Restoring the Operating System
115
Software Options
117
Changing Software Option Key
117
Scope ID, Scope Serial Number
117
Entering Option Key in the DSO
117
Board Exchange Procedure
118
Processor Board Exchange Procedure
118
Hard Drive Replacement Procedure
118
Equipment and Spare Parts Recommended for Service
119
Test Equipment Required
119
Waverunner Spare Parts
119
Service Menu
120
Accessing Service Menu
120
Mainframe Tests
121
Front Panel Test
121
Critical File Backup
123
Acquisition System Tests
124
Critical Acquisition System Component Temperatures
124
Automatic Calibrations
125
Calibration Procedures
126
System Power Supply Calibration Procedure
126
Touch Screen Calibration Procedure
130
Troubleshooting and Flow Charts
133
Introduction
133
Repair Level
133
Initial Troubleshooting
134
Power Supply Problem
136
No Display (Internal or External)
139
Internal Display Problem
140
Boot up Sequence
141
Front Panel Controls Do Not Operate
142
Touch Screen Problems
143
Timebase Problem
145
Remote Control Problem
146
CD-ROM Problem
147
Vertical Accuracy Problem
148
Advertisement
Related Products
LeCroy WaveRunner Xi-A
LeCroy WaveRunner MXi-A
LeCroy WaveRunner XI Series
LeCroy Waverunner2 Series
LeCroy Waverunner2 LT372 Series
LeCroy Waverunner2 LT262 Series
LeCroy Waverunner2 LT584 Series
LeCroy Waverunner2 LT374 Series
LeCroy Waverunner2 LT354 Series
LeCroy Waverunner2 LT264 Series
LeCroy Categories
Test Equipment
Measuring Instruments
Amplifier
Accessories
Inverter
More LeCroy Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL