5. PARAMETERS
Class No. Symbol
Function selection 1
2
*OP1
Used to select the input filter and absolute position detection system.
Auto tuning
3
ATU
Used to selection the response level, etc. for execution of auto tuning.
(Refer to Chapter 7)
0
Set value Gain adjustment mode
Name and Function
0 0
Input filter
If external input signal causes chattering due
to noise, etc., input filter is used to suppress it.
0: None
1: 0.88[ms]
2: 1.77[ms]
3: 2.66[ms]
4: 3.55[ms]
5: 4.44[ms]
Selection of absolute position detection system
(Refer to Section 4.5)
0: Incremental system
1: Absolute position detection system
0
Auto tuning response level setting
Set
Response
value
level
Low
1
response
2
3
4
5
6
7
Middle
8
response
9
A
B
C
D
High
E
response
F
If the machine hunts or generates large gear sound,
decrease the set value.
To improve performance, e.g. shorten the settling time,
increase the set value.
Gain adjustment mode selection
(For more information, refer to Section 8.1.1.)
GD2 (parameterNo.34), PG2 (parameterNo.35),
0
Interpolation mode
VG2 (parameterNo.37), VIC (parameterNo.38)
1
Auto tuning mode 1
PG1 (parameterNo.7), GD2 (parameterNo.35),
PG2 (parameterNo.35), VG1 (parameterNo.36),
VG2 (parameterNo.37), VIC (parameterNo.38)
2
Auto tuning mode 2
PG1 (parameterNo.7), PG2 (parameterNo.35),
VG1 (parameterNo.36), VG2 (parameterNo.37),
VIC (parameterNo.38)
PG2 (parameterNo.35)
3
Manual mode 1
4
Manual mode 2
Machine resonance
frequency guideline
15Hz
20Hz
25Hz
30Hz
35Hz
45Hz
55Hz
70Hz
85Hz
105Hz
130Hz
160Hz
200Hz
240Hz
300Hz
Description
5 - 7
Initial
Setting
Unit
value
range
0002
Refer to
Name
and
function
column.
0105
Refer to
Name
and
function
column
.