External Digital Display (Mr-Dp60) - Mitsubishi Electric Melservo-J2-SUPER series Instruction Manual

General-purpose ac servo
Hide thumbs Also See for Melservo-J2-SUPER series:
Table of Contents

Advertisement

14. OPTIONS AND AUXILIARY EQUIPMENT

14.1.7 External digital display (MR-DP60)

When using the MR-DP60, set " 1 4" in parameter No. 16.
(1) Specifications
Display
Power supply
Permissible voltage fluctuation
Current consumption
Communication
Interface
Baudrate
Bit length
Protocol
Communication commands
Operating temperature / humidity range
Storage temperature range
(2) Connection example
NFB
Power supply
200 to 230VAC
(3) Terminal arrangement
TB1
TXD TXD RXD RXD P5 LG
Note: The 5VDC output is designed for the internal control circuit and used to make a voltage check, etc. Do not use this terminal to
supply a voltage to the other equipment.
Item
Red seven-segment LED, signed, six digits
Single phase, 85 to 253VAC, 50/60Hz
Within 200mA
Conforms to RS-422A.
4800bps, asynchronous
Start bit 1, date bit 8, parity bit 1, stop bit 1
MELSERVO protocol
Commands dedicated to MELSERVO
0
to 60 , 90%RH or less, non-condensing
5
to 70
L
1
L
2
Servo amplifier
L
3
L
11
L
21
CN3
RDP
5
RDN
15
9
SDP
19
SDN
P24M
1
Plate
SD
Signal
TB2
L
1
RXD
L
2
RXD
TXD
TXD
14 - 26
Specifications
Description
L
1
100 to 230VAC power input
L
2
Ground
Receive signal input
Inverse receive signal input
Inverse transmission signal output
Transmission signal output
P5
5VDC output (Note)
LG
Control common
External digital display
MR-DP60
L
1
L
2
TXD
TXD
RXD
RXD
LG

Hide quick links:

Advertisement

Table of Contents
loading