Switch Fabric Settings

42
Switch Fabric Settings There are a number of settings control the overall
This section provides information on switch fabric settings.
Field
Domain
BB Credit
R_A_TOV
E_D_TOV
Data Field Size
Non-SCSI Tachyon Mode
Disable Device Probing
Unicast-only Operation
VC Encoded Address Mode Boolean 0
Disable Translative Mode
Per-frame Route Priority
behavior and operation of the fabric. Some of
these values, such as the domain, are assigned
automatically by the fabric and may differ from
one switch to another in the fabric. Other
parameters, such as the buffer-to-buffer credit or
the time-out values, can be changed for specific
applications or operating environments, but must
be in agreement among all switches to allow
formation of the fabric.
The table in the next section defines settings that
can be changed.
Type
Default
Number
1
Number
16
Number
10000
Number
2000
Number
2112
Boolean 0
Boolean 0
Boolean 0
Boolean 0
Boolean 0
Range
Varies
1 to 16
E_D_TOV * 2 to
120000
1000 to R_A_TOV / 2
256 to 2112
0 or 1
0 or 1
0 or 1
0 or 1
0 or 1
0 or 1