diagShow

Synopsis
Availability
Description
62
Print diagnostic results since the last boot.
diagShow [nSeconds]
All users
Use this command to print the following information generated since the
last switch reboot:
• State of all ports in the switch resulting from diagnostics run since the
last reboot. Ports that passed diagnostic testing are marked OK. Ports
that failed one or more diagnostic tests are marked BAD.
• Current state of ports. Active ports are UP and inactive ports are DN.
• Frame counts for active ports – the number of frames transmitted is
and the number of frames received is
frTx
The "
" is the total of the port's eight statistic error counters:
LLI_errs
ENC_in, CRC_err, TruncFrm, FrmTooLong, BadEOF,
Enc_out, BadOrdSet, DiscC3.
• State of central memory based on the results of diagnostics run since the
last reboot. OK if previous centralMemoryTest executions passed;
FAULTY if the switch failed
• Total diagnostic frames transmitted and received since last reboot.
The totals represent the cumulative number of frames transmitted and
received by the diagnostic functional tests (
crossPortTest,
ports since the last reboot. (If the switch is rebooted with POST
disabled,
diagShow
The transmitted and received values may not always be the same; for
example, they may not be the same if an error occurred in one of the
ports during one of the tests above.
This command can also be executed by using the
QCSL diag prompt, which is generated when a diagnostic test is keyboard
interrupted.
centralMemoryTest
or
for the transmitted count only) for all
spinSilk
indicates the total as
.
frRx
.
portLoopbackTest
.)
0
(Stats) option of the
s
Fabric OS Reference Manual
,