Cmemretentiontest - HP Surestore 6164 - Switch Reference Manual

Fabric os
Hide thumbs Also See for Surestore 6164 - Switch:
Table of Contents

Advertisement

cmemRetentionTest

Synopsis
Availability
Description
Operands
Example
Errors
See Also
Telnet Commands
Data retention test of the central memory SRAMs.
cmemRetentionTest [passCount]
admin
Use this command to verify for data retention in the central memory
SRAMs in the ASIC.
This command cannot be executed on an operational switch. You
Note
must first disable the switch using the switchDisable command.
This command has the following operand:
Specify the number of times to execute this test. The
passCount
default value is 1. This operand is optional.
To run the data retention test on the central memory SRAMS:
switch:admin> cmemRetentionTest
Running CMEM Retention Test ... passed.
There are three possible error messages if failures are detected:
DIAG-LCMRS
DIAG-LCMTO
DIAG-LCMEM
camTest
centralMemoryTest
cmiTest
crossPortTest
portLoopbackTest
ramTest
spinSilk
sramRetentionTest