HP Surestore 6164 - Switch Reference Manual page 171

Fabric os
Hide thumbs Also See for Surestore 6164 - Switch:
Table of Contents

Advertisement

Operands
Example
Telnet Commands
At each pass, the frame is created from a different data type. If seven passes
are requested, seven different data types are used in the test. If eight passes
are requested, the first seven frames use unique data types, and the eighth is
the same as the first. There are seven data types:
1.
:
CSPAT
0x7e, 0x7e, 0x7e, 0x7e, ...
2.
:
BYTE_LFSR
0x69, 0x01, 0x02, 0x05, ...
3.
:
CHALF_SQ
0x4a, 0x4a, 0x4a, 0x4a, ...
4.
:
QUAD_NOT
0x00, 0xff, 0x00, 0xff, ...
5.
:
CQTR_SQ
0x78, 0x78, 0x78, 0x78, ...
6.
:
CRPAT
0xbc, 0xbc, 0x23, 0x47, ...
7.
:
RANDOM
0x25, 0x7f, 0x6e, 0x9a, ...
Because this test does not include the GBIC and the fiber cable in its test
path, use the results from this test in conjunction with the results from
and
crossPortTest
components that are not functioning properly.
This command has the following operand:
Specify the number of times (or number of frames per
passCount
port) to execute this test. The default value is
0xfffffffe
To run the portLoopbackTest 100 times:
switch:admin> portLoopbackTest 100
Running Port Loopback Test .... passed.
test to determine those switch
spinSilk
. This operand is optional.
171