Virtual Channel Settings

46
The switch provides the ability to tune it in a specific application, by
configuring the parameters for its eight virtual channels. Note that the first
two virtual channels are reserved for switch internal functions and are not
user-configurable.
The default virtual channel settings have already been optimized for switch
performance. Changing the default values can improve switch
performance, but it can also degrade performance. Do not change these
settings without fully understanding the effects of the changes.
Table 2. Virtual Channel Settings
Field
VC Link Control
VC Class 2
VC Class 3
VC Multicast
VC Priority 2
VC Priority 3
VC Priority 4
VC Priority 5
VC Priority 6
VC Priority 7
Here are descriptions of the Virtual Channel Setting fields:
VC Link Control Specifies the virtual channel used for
N_Port
P_BSY
control frames to be sent using a Class 2 data Virtual
Channel when set to 0. When set to 1, the control
frames are sent using a Virtual Channel normally
reserved for fabric-internal traffic. This setting is
configurable only when VC Encoded Address Mode
is set.
Type
Number
Number
Number
Number
Number
Number
Number
Number
Number
Number
-generated, Class 2 link control frames (
s,
s). Forces
P_RJT
N_Port
Default
Range
0
0 to 1
2
2 to 5
3
2 to 5
7
6 to 7
2
2 to 3
2
2 to 3
2
2 to 3
2
2 to 3
3
2 to 3
3
2 to 3
-generated link