HP Surestore 6164 - Switch Reference Manual page 260

Fabric os
Hide thumbs Also See for Surestore 6164 - Switch:
Table of Contents

Advertisement

Table 18. Diagnostic Error Messages (continued)
Message
DIAG-CLEAR_ERR
Err#0001
DIAG-CMBISRF
Err#1021
[centralMemoryTest]
DIAG-CMBISRTO
Err#1020
[centralMemoryTest]
DIAG-CMERRPTN
Err#102B
[centralMemoryTest]
DIAG-CMERRTYPE
Err#102A
[centralMemoryTest]
DIAG-CMICKSUM
Err#2036
[cmiTest]
DIAG-CMIDATA
Err#2035
[cmiTest]
260
Description
Port diag error flag (OK or BAD)
is cleared
ASIC Central Memory SRAMs
did not complete the BISR within
the time-out period
ASIC Central Memory SRAMs
did not complete the BISR within
the time-out period
Error detected at the wrong port
Port got the wrong CMEM error
type
CMI message received failed bad
checksum test
CMI data received did not match
data transmitted
Probable Cause
Action
Informational
None required
only
ASIC failure
Replace
mainboard
assembly
ASIC failure
Replace
mainboard
assembly
ASIC failure
Replace
mainboard
assembly
ASIC failure
Replace
mainboard
assembly
ASIC or
Replace
mainboard
mainboard
failure
assembly
ASIC or
Replace
mainboard
mainboard
failure
assembly
Fabric OS Reference Manual