Mac Address Station Move; Mac Move Optimization - Dell PowerEdge M IO Aggregator Command Reference Manual

Mxl 10/40gbe switch io module ftos command reference guide, ftos 8.3.16.1
Hide thumbs Also See for PowerEdge M IO Aggregator:
Table of Contents

Advertisement

Figure 13-1. Redundant NICs with NIC Teaming
MAC: A:B
A:B:C:D
IP: 1.1.1.1

MAC Address Station Move

When you use NIC teaming, consider that the server MAC address is originally learned on Port 0/1 of the
switch
(Figure
13-2). If the NIC fails, the same MAC address is learned on Port 0/5 of the switch. The
MAC address is disassociated with the one port and re-associated with another in the ARP table; in other
words, the ARP entry is "moved". The Aggregator is auto-configured to support MAC Address station
moves.
Figure 13-2. MAC Address Station Move
MAC: A:B
A:B:C:D
IP: 1.1.1.1
mac-address-table station-move refresh-arp
configured at time of NIC teaming

MAC Move Optimization

Station-move detection takes 5000ms because this is the interval at which the detection algorithm runs.
X
X
Move MAC
address
Port 0/1
Port 0/5
Port 0/1
Port 0/5
fnC0025mp