The Error Group
This group consists of tables that contain information about the various types of errors detected.
The management station may use the information in this group to determine the quality of the link
between the FxPort and its attached NxPort.
Implementation of this group is optional.
FxPort Error Table
This table contains, one entry for each FxPort in the Fabric Element and counters recording
numbers of errors detected since the management agent re-initialized.
Note:
fcFxPortErrorTable
Syntax
Sequence of FcFxPortErrorEntry
Access
Not accessible
Status
Mandatory
Description
A table that contains, one entry for each FxPort, counters that record the numbers of errors
detected.
MIB Reference Manual Version 3.0
The first 6 columnar objects after the port index corresponds to the counters in the Link
ErrorStatus Block.
FCFabric Element MIB Object Types
3