connUnitPortStatCountLinkFailures [connUnitPortStatTable]
Syntax
Octet String of size 8
Access
Read-only
Status
Mandatory
Description
The number of link failures. This count is part of the Link Error Status Block (LESB). (FC-PH
29.8)
Note:
connUnitPortStatCountInvalidCRC [connUnitPortStatTable]
Syntax
Octet String of size 8
Access
Read-only
Status
Mandatory
Description
The number of frames received with invalid CRC. This count is part of the Link Error Status Block
(LESB). (FC-PH 29.8) Loop ports should not count CRC errors passing through when monitoring.
Note:
connUnitPortStatCountInvalidTxWords [connUnitPortStatTable]
Syntax
Octet String of size 8
Access
Read-only
Status
Mandatory
Description
The number of invalid transmission words received at this port. This count is part of the Link Error
Status Block (LESB). (FC-PH 29.8)
Note:
2-70
This is a Fibre Channel only stat.
This is a Fibre Channel only stat.
This is a Fibre Channel only stat.