tcpRtoMax
Syntax
Integer
Access
Read-only
Status
Mandatory
Description
The maximum value permitted by a TCP implementation for the retransmission time-out, measured
in milliseconds.
Note:
tcpMaxConn
Syntax
Integer
Access
Read-only
Status
Mandatory
Description
The limit on the total number of TCP connections the entity can support. In entities where the
maximum number of connections is dynamic, this object should contain the value -1.
tcpActiveOpens
Syntax
Counter
Access
Read-only
Status
Mandatory
Description
The number of times TCP connections have made a direct transition to the SYN-SENT state from
the CLOSED state.
tcpPassiveOpens
Syntax
Counter
Access
Read-only
Status
Mandatory
Description
The number of times TCP connections have made a direct transition to the SYN-RCVD state from
the LISTEN state.
MIB Reference Manual Version 3.0
More refined semantics for objects of this type depend upon the algorithm used to
determine the retransmission time-out. In particular, when the time-out algorithm is rsre
(3), an object of this type has the semantics of the UBOUND quantity described in RFC
793.