fcFxPortErrorFxPortIndex [fcFxPortErrorTable]
Syntax
FcFeFxPortIndex
Access
Read-only
Status
Mandatory
Description
Identifies the FxPort within the module. This number ranges from 1 to the value of
fcFeModulePortCapacity for the associated module. The value remains constant for the identified
FxPort until the module is re-initialized.
fcFxPortLinkFailures [fcFxPortErrorTable]
Syntax
Counter
Access
Read-only
Status
Mandatory
Description
The number of link failures detected by this FxPort.
fcFxPortSyncLosses [fcFxPortErrorTable]
Syntax
Counter
Access
Read-only
Status
Mandatory
Description
The number of loss of synchronization detected by the FxPort.
fcFxPortSigLosses [fcFxPortErrorTable]
Syntax
Counter
Access
Read-only
Status
Mandatory
Description
The number of loss of signal detected by the FxPort.
MIB Reference Manual Version 3.0
FCFabric Element MIB Object Types
3
3-35