HP StorageWorks 8B - FC Entry Switch Reference Manual page 309

Mib reference manual (version 3.0)
Hide thumbs Also See for StorageWorks 8B - FC Entry Switch:
Table of Contents

Advertisement

swSensorScn (Obsoleted by swFabricWatchTrap)
Enterprise
sw
Variables
swSensorStatus, swSensorIndex, swSensorType, swSensorValue, swSensorInfo
Description
A 2 (swSensorScn) is generated whenever an environment sensor changes its operational state. For
instance, a fan stop working. The VarBind in the Trap Data Unit shall contain the corresponding
instance of the sensor status, sensor index, sensor type, sensor value (reading) and sensor
information. Note that the sensor information contains the type of sensor and its number in textual
format.
#TYPE
#SUMMARY
#ARGUMENTS
#SEVERITY
#TIMEINDEX
#STATE
swFCPortScn
Enterprise
sw
Variables
swFCPortOpStatus, swFCPortIndex
Description
A 3 (swFCPortScn) is generated whenever an FC_Port changes its operational state. For instance,
the FC_Port goes from on-line to offline. The VarBind in the Trap Data Unit shall contain the
corresponding instance of the FC_Port's operational status and index.
#TYPE
#SUMMARY
#ARGUMENTS
#SEVERITY
#TIMEINDEX
#STATE
MIB Reference Manual Version 3.0
A sensor (temperature, fan, or other) changed its operational state.
%s: is currently in state %d
4, 0
Informational
1
Operational
A Fibre Channel Port changed its operational state.
Port Index %d changed state to %d
1, 0
Informational
1
Operational
FCSwitch MIB Object Types