Connectivity Unit Table
connUnitTable
Syntax
Sequence of connUnitEntry
Access
Not accessible
Status
Mandatory
Description
A list of units under a single SNMP agent. The number of entries is given by the value of uNumber.
The value is 1 for stand-alone system.
Note:
connUnitEntry [connUnitTable]
Syntax
connUnitEntry
Access
Not accessible
Status
Mandatory
Description
A connectivity unit entry containing objects for a particular unit.
Index
connUnitId
Table 2-2
connUnitId: 2-11
connUnitGlobalId: 2-11
connUnitType: 2-12
connUnitNumports: 2-13
connUnitState: 2-13
connUnitStatus: 2-14
connUnitProduct: 2-14
connUnitSn: 2-15
connUnitUpTime: 2-15
connUnitUrl: 2-15
connUnitDomainId: 2-16
connUnitProxyMaster: 2-16
connUnitPrincipal: 2-17
connUnitNumSensors: 2-17
MIB Reference Manual Version 3.0
The valid value for the FC Entry Switch 8B, FC Switch 8B, or FC 16B: 1
connUnitEntry Objects and Object Types
Fibre Alliance MIB Object Types
Octet String
FcGlobalId
FcUnitType
Integer
Integer
Integer
Display String
Display String
TimeTicks
Display String
Octet String
Integer
Integer
Integer