HP StorageWorks 8B - FC Entry Switch Reference Manual page 264

Mib reference manual (version 3.0)
Hide thumbs Also See for StorageWorks 8B - FC Entry Switch:
Table of Contents

Advertisement

4
FCSwitch MIB Object Types
swFCPortLipOuts [swFCPortTable]
Syntax
Counter
Access
Read-only
Status
Mandatory
Description
Counts the number of Loop Initializations that has been initiated by the port.
swFCPortLipLastAlpa [swFCPortTable]
Syntax
Octet String of size 4
Access
Read-only
Status
Mandatory
Description
Indicates the Physical Address (AL_PA) of the loop device that initiated the last Loop
Initialization.
swFCPortWwn [swFCPortTable]
Syntax
Octet String of size 8
Access
Read-only
Status
Mandatory
Description
The WWN of the Fibre Channel port. The contents of an instance are in the IEEE extended format
as specified in FC-PH.
swFCPortSpeed [swFCPortTable]
Syntax
Value
Integer
Access
Read-write
Status
Mandatory
Description
The desired baud rate for the port.
4-42
Declaration
Description
1 (one-GB)
2 (two-GB)
3 (auto-Negotiate)
MIB Reference Manual Version 3.0