connUnitPortStatCountTxElements [connUnitPortStatTable]
Syntax
Octet String of size 8
Access
Read-only
Status
Mandatory
Description
The number of octets or bytes that have been transmitted by this port. One second periodic polling
of the port. This value is saved and compared with the next polled value to compute net throughput.
Note:
connUnitPortStatCountRxElements [connUnitPortStatTable]
Syntax
Octet String of size 8
Access
Read-only
Status
Mandatory
Description
The number of octets or bytes that have been received. by this port. One second periodic polling of
the port. This value is saved and compared with the next polled value to compute net throughput.
Note:
connUnitPortStatCountBBCreditZero [connUnitPortStatTable]
Syntax
Octet String of size 8
Access
Read-only
Status
Mandatory
Description
The number of transitions in/out of BBcredit zero state. The other side is not providing any credit.
Note:
connUnitPortStatCountInputBuffersFull [connUnitPortStatTable]
Syntax
Octet String of size 8
Access
Read-only
Status
Mandatory
Description
The number of occurrences when all input buffers of a port were full and outbound buffer-to-buffer
credit transitioned to zero. There is no credit to provide to other side.
Note:
MIB Reference Manual Version 3.0
For Fibre Channel, ordered sets are not included in the count.
For Fibre Channel, ordered sets are not included in the count.
This is a Fibre Channel stat only.