swSensorInfo [swSensorTable]
Syntax
Display String of size 0 to 255
Access
Read-only
Status
Mandatory
Description
Additional displayable information on the sensor. In V2.x, it contains the sensor type and number
in textual format. For example, Temp 3 or Fan 6.
Note:
swTrackChangesInfo
Syntax
Display String of size 0 to 256
Access
Read-only
Status
Mandatory
Description
Track changes string. For trap only.
Note:
MIB Reference Manual Version 3.0
For swSensorIndex 1 through 5, valid return values include:
•
Temp #1
•
Temp #2
•
Temp #3
•
Temp #4
•
Temp #5
For swSensorIndex 6 through 11, valid return values include:
•
Fan #1
•
Fan #2
•
Fan #3
•
Fan #4
•
Fan #5
•
Fan #6
For swSensorIndex 12 and 13, valid return values include:
•
Power Supply #1
•
Power Supply #2
If there are no events to track, the default return value is "No event so far".
If there are events to track, the following are valid return values:
•
Successful login
•
Unsuccessful login
•
Logout
•
Configuration file change from task [name of task]
•
Track-changes on
•
Track-changes off