connUnitPrincipal [connUnitTable]
Syntax
Integer
Table 2-6
Value
Integer
Access
Read-only
Status
Mandatory
Description
Whether this connectivity unit is the principal unit within the group of fabric elements. If this value
is not applicable, return unknown.
Note:
connUnitNumSensors [connUnitTable]
Syntax
Integer
Access
Read-only
Status
Mandatory
Description
Number of sensors in the connUnitSensorTable.
Note:
connUnitStatusChangeTime [connUnitTable]
Syntax
TimeTicks
Access
Read-only
Status
Deprecated
Description
The sysuptime timestamp (in centiseconds) at which the last status change occurred for any
members of the set. In other words, this is the latest timestamp that connUnitStatus or
connUnitPortStatus changed.
Note:
MIB Reference Manual Version 3.0
Declaration
Description
1 (unknown)
2 (no)
3 (yes)
If the switch is principal, this is set to 3 (yes), otherwise, it is set to 2 (no).
The number of sensors for the FC Entry Switch 8B and FC Switch 8B: 11 (5 temp + 5
fans + 1 power supply).
The number of sensors for the FC 16B: 13 (5 temp + 6 fans + 2 power supplies).
This is the same as statusChangeTime.