fcFxPortClass2SeqDelivAgreed [fcFxlogiTable]
Syntax
Value
Integer
Access
Read-only
Status
Mandatory
Description
A variable indicating whether the FxPort has agreed to support Class 2 sequential delivery from the
Fabric Login. This is only meaningful if Class 2 service has been agreed.
fcFxPortClass3SeqDelivAgreed [fcFxlogiTable]
Syntax
Value
Integer
Access
Read-only
Status
Mandatory
Description
A flag indicating whether the FxPort has agreed to support Class 3 sequential delivery from the
Fabric Login. This is only meaningful if Class 3 service has been agreed.
fcFxPortNxPortName [fcFxlogiTable]
Syntax
FcPortName
Access
Read-only
Status
Mandatory
Description
The port name of the attached NxPort, if applicable. If the value of this object is
'0000000000000000'H, this FxPort has no NxPort attached to it.
MIB Reference Manual Version 3.0
Declaration
Description
1 (yes)
The FxPort has agreed to support Class 2 sequential
delivery from the Fabric Login.
2 (no)
The FxPort has not agreed to support Class 2 sequential
delivery from the Fabric Login.
Declaration
Description
1 (yes)
The FxPort has agreed to support Class 3 sequential
delivery from the Fabric Login.
2 (no)
The FxPort has not agreed to support Class 3 sequential
delivery from the Fabric Login.