The Connectivity Group - HP StorageWorks 8B - FC Entry Switch Reference Manual

Mib reference manual (version 3.0)
Hide thumbs Also See for StorageWorks 8B - FC Entry Switch:
Table of Contents

Advertisement

The Connectivity Group

Implementation of the Connectivity group is mandatory for all systems.
uNumber
Syntax
Integer
Access
Read-only
Status
Mandatory
Description
The number of connectivity units present on this system (represented by this agent). May be a
count of the boards in a chassis or the number of full boxes in a rack.
Note:
systemURL
Syntax
Display String
Access
Read-only
Status
Mandatory
Description
The top-level URL of the system. If it does not exist the value is empty string. The URL format is
implementation dependant and can have keywords embedded that are preceded by a percent sign
(for example,%USER).
The following are the defined keywords that are recognized and replaced with data during a launch:
USER
PASSWORD
GLOBALI
SERIALNO
DEFVAL
Note:
MIB Reference Manual Version 3.0
The connectivity unit is mapped to a switch.
uNumber is always set to 1.
Replace with username
Replace with password
Replace with globalid
Replace with serial number
{""}
The expected value for systemURL.0 is:
"http://{a.b.c.d}"
where {a.b.c.d} is the IP address of the switch.
"" (null)
Fibre Alliance MIB Object Types
2
2-7

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storageworks fc entry switch 8b

Table of Contents