swFwCustUnit [swFwClassAreaTable]
Syntax
Display String of size 0 to 256
Access
Read-write
Status
Mandatory
Description
A customizable unit string name, used to identify the unit of measure for a Fabric Watch classArea
combination. For example:
•
C = environment (class), temperature (area).
•
RPM = environment (class), fan (area).
swFwCustTimebase [swFwClassAreaTable]
Syntax
SwFwTimebase
Access
Read-write
Status
Mandatory
Description
A customizable polling period for the Fabric Watch classArea combination. For example:
•
swFwTbMin = port (class), link loss (area).
•
swFwTbNone = environment (class), temperature (area).
swFwCustLow [swFwClassAreaTable]
Syntax
Integer
Access
Read-write
Status
Mandatory
Description
A customizable low-threshold value for a Fabric Watch ClassArea combination.
swFwCustHigh [swFwClassAreaTable]
Syntax
Integer
Access
Read-write
Status
Mandatory
Description
A customizable high-threshold value for a Fabric Watch ClassArea combination.