2
Fibre Alliance MIB Object Types
connUnitPortStatCountInvalidOrderedSets [connUnitPortStatTable]
Syntax
Octet String of size 8
Access
Read-only
Status
Mandatory
Description
The number of invalid ordered sets received at port. This count is part of the Link Error Status
Block (LESB). (FC-PH 29.8).
Note:
connUnitPortStatCountFramesTooLong [connUnitPortStatTable]
Syntax
Octet String of size 8
Access
Read-only
Status
Mandatory
Description
The number of frames received at this port where the frame length was greater than what was
agreed to in
FLOGI/PLOGI. This could be caused by losing the end of frame delimiter.
Note:
connUnitPortStatCountFramesTruncated [connUnitPortStatTable]
Syntax
Octet String of size 8
Access
Read-only
Status
Mandatory
Description
The number of frames received at this port where the frame length was less than the minimum
indicated by the frame header - normally 24 bytes, but it could be more if the DFCTL field
indicates an optional header should have been present.
Note:
2-72
This is a Fibre Channel only stat.
This is a Fibre Channel only stat.
This is a Fibre Channel only stat.