4
FCSwitch MIB Object Types
swFwActLevel [swFwClassAreaTable]
Syntax
SwFwLevels
Access
Read-write
Status
Mandatory
Description
swFwActLevel is used to point to the current level for classArea values. It is either default or
custom
Note:

Fabric Watch Threshold Table

swFwThresholdTable
Syntax
Sequence of SwFwThresholdEntry
Access
Not accessible
Status
Mandatory
Description
The table of individual thresholds.
4-62
For a read operation, the return value is either 2 (swFwDefault) or 3 (swFwCustom). 1
(swFwReserved) is obsolete.
If the write operation sets the variable to 2 (swFwDefault), the following default action
matrix variables are used for the Fabric Watch classArea combination:
swFwDefaultChangedActs
swFwDefaultExceededActs
swFwDefaultBelowActs
swFwDefaultAboveActs
swFwDefaultInBetweenActs
If the write operation sets the variable to 3 (swFwCustom), the following custom action
matrix variables are used for the Fabric Watch classArea combination:
swFwCustChangedActs
swFwCustExceededActs
swFwCustBelowActs
swFwCustAboveActs
swFwCustInBetweenActs