3
FCFabric Element MIB Object Types
fcFeModuleLastChange [fcFeModuleTable]
Syntax
TimeTicks
Access
Read-only
Status
Mandatory
Description
Contains the value of sysUpTime when the module entered its current operational status. A value of
zero indicates that the operational status of the module has not changed since the agent last
restarted.
fcFeModuleFxPortCapacity [fcFeModuleTable]
Syntax
FcFeFxPortCapacity
Access
Read-only
Status
Mandatory
Description
The number of FxPort that can be contained within the module. Within each module, the ports are
uniquely numbered in the range from 1 to fcFeModuleFxPortCapacity inclusive. However, the
numbers are not required to be contiguous.
Note:
fcFeModuleName [fcFeModuleTable]
Syntax
FcNameId
Access
Read-only (instead of read-write)
Status
Mandatory
Description
The Name_Identifier of the module.
Note:
3-12
The valid value for FC Entry Switch 8B and FC Switch 8B: 8
The valid value for FC 16B: 16
The return value is the WWN of the switch.
MIB Reference Manual Version 3.0