5.
Install the VRMs into their sockets. Press the VRM evenly and firmly. When properly installed,
the socket tabs will hook over the notches inside of the VRM.
6.
Close the base unit and restart the system. The number of installed processors displays at the blue
Windows NT boot screen.
NOTE
If the new processors do not display, ensure the VRMs and processors are fully seated in their sockets.

Converting a Non-RAID System to RAID

If your system uses non-RAID disk drives, you can convert it to use RAID drives by swapping the non-
RAID components with their RAID counterparts.
To convert a non-RAID system to RAID:
1.
Remove the right side panel.
2.
Disconnect the two SCSI cables from the UW SCSI controller.
3.
Remove the UW SCSI controller.
4.
Install AMI RAID controller in slot previously occupied by the UW SCSI controller.
5.
Connect the SCSI cables from the disk section to the RAID controller. The cable attached to CH 0
on the disk section must connect to CH 0 on the RAID controller (and the same for CH 1).
UW SCSI
Controller
SCSI
Cables
37